SATO 10e User Manual

Page of 126
Section 5: Printer Configuration
SATO M10e Service Manual
PN 9001113A
Page 5-23
CLEAR NON-STANDARD PROTOCOL
The standard protocol codes used by the printer can be modified to accomodate the requirements of
different host systems. However, if the printer is to be used with a system that does not use the custom
protocol codes, they can be cleared and the default protocol codes reactivated. The default values are:
STX = 7BH, ETX = 7DH, ESC = 5EH, ENQ = 40H, NULL = 7EH, CAN = 21H and OFFLINE = 5DH.
LCD DISPLAY
DEFINITION
V 05.00.03.00
INITIALIZING
Displays the firmware during the initialization.
ALT.PROTOCOL
DEFAULT COMPLETE
To Clear Non-Standard protocol codes:
1.   Place DSW2-7 in the On position.
2. Press and hold the LINE and FEED keys while switching on the printer.
3. Release the LINE and FEED keys when the printer emits one long beep.
4. Standby for the printer to replace the Alternate protocol codes with the
default values.
The printer will emit two short beeps when the process is complete. To exit the
mode, power the printer off and then back on.
DOWNLOAD USER DEFINED PROTOCOL CODES
The user can define a set of custom protocol codes and download them to the printer using the <ESC>LD
command.
LCD DISPLAY
DEFINITION
V 05.00.03.00
INITIALIZING
Displays the firmware during the initialization.
USER DOWNLOAD
PRESS THE LINE KEY
Allows the replacement of the Standard Protocol Codes or the Alternate set of
Protocol Codes. To enter the User Download mode: 
1. Place DSW2-7 in the on position.
2. Press and hold the LINE and FEED keys while switching on the power.
3. Release the LINE and FEED keys when the printer emits one long beep.
USER DOWNLOAD
WAITING
4. Press the LINE key. The printer is now waiting for the data to be sent.
5. Transmit the download data command stream to the printer.
After the data has been received, the printer will beep and print a status label.
If it does not beep and print a status label, the printer did not accept the data.
If the printer did not beep and print a status label, turn the printer off and check
your data stream for errors and start the download process over.
If the custom codes are correct, press the ENTER key to select and terminate
the download process. If they are incorrect, turn the printer off without
pressing the ENTER key and begin the process again.