Functions 
 
11.4 Watchdog (WD) 
SIMATIC Panel PC 877 
Operating instructions, Release 07/2006, A5E00877780-01 
11-5
 
11.4 
11.4 
Watchdog (WD) 
 
Function 
The watchdog monitors the program execution and reports a program crash to the user by 
means of various reactions. 
The watchdog is idle when the PC is switched on or after a HW-RESET(cold restart), i.e., no 
reaction of the WD is triggered. 
WD reactions 
If the WD is not triggered again within the set time (by driver or SOM program), the following 
reactions are initiated: 
 
Response 
Option 
WD acknowledgement 
None 
Trigger a PC reset 
Configurable 
SOM or DiagMonitor software is activated 
None 
WD monitor times (TWD) 
The TWD are adjustable in increments of one second in a range from 3 to 255 seconds. 
 
 
Note 
If the watchdog time is changed after the watchdog was enabled (i.e., while the watchdog is 
running), the watchdog is retriggered!