Siemens PANEL PC 877 User Manual

Page of 288
Detailed descriptions 
 
17.1 Motherboard 
 
SIMATIC Panel PC 877 
17-16
 
Operating instructions, Release 07/2006, A5E00877780-01 
I/O front interface for operator panels, X44 
This interface carries all signals required for the connection of operator panels in addition to 
the display and USB interface. The maximum cable length is 50 cm at a USB data rate of 12 
Mbps. 
 
Pin No. 
Abbreviation 
Meaning 
Input/Output 
GND 
Ground 
P12V 
Inverter voltage supply 
Output 
BL_ON 
Backlight ON (5 V = ON) 
Output 
P5V_fused 
+5 V (fused) 
Output 
GND 
Ground 
P3V3_fused 
+3.3 V VCC (fused) 
Output 
K_CLK 
Keyboard clock channel 
Output 
K_DATA 
Keyboard data channel 
Input/Output 
M_CLK 
Mouse clock channel 
Output 
10 
K_DATA 
Mouse data channel 
Input/Output 
11 
P5V_fused 
+5 V (fused) 
Output 
12 
USB_D1M 
USB data channel 1 
Input/Output 
13 
USB_D1P 
USB data+, channel 1 
Input/Output 
14 
GND 
Ground 
15 
LCD_SEL0 
Display type - Select signal 0 
Input 
16 
LCD_SEL1 
Display type - Select signal 1 
Input 
17 
LCD_SEL2 
Display type - Select signal 2 
Input 
18 
LCD_SEL3 
Display type - Select signal 3 
Input 
19 
RESET_N 
Reset signal (active low) 
Input 
20 
Power button 
Power button function front 
Input 
21 
HD_LED 
HD LED, anode with 1 kW in series on the 
motherboard 
Output 
22 
DP_LED 
MPI/DP LED, anode via 1 kohm in series on the 
motherboard 
Output 
23 
Ethernet_LED 
Ethernet LED, anode with 1 kW in series on the 
motherboard 
Output 
24 
TEMP_ERR 
Temperature error LED, anode with 1 kW in series 
on the motherboard 
Output 
25 
RUN_R 
Watchdog error LED, anode with 1 kW in series on 
the motherboard 
Output 
26 
RUN_G 
Watchdog OK LED, anode with 1 kW in series on 
the motherboard 
Output