17.2 Bus board 
SIMATIC Panel PC 877 
Operating instructions, Release 07/2006, A5E00877780-01 
17-25
 
17.2.2 
Assignment of the PCI IRQ channels to the PCI slots 
Assignment of the PCI IRQ channels to the PCI slots 
 
Box PC 840 V2 
PCI modules interrupt assignment (PCI IRQ) in: 
Module interrupt (Pin 
No.) 
Slot 1 
Slot 2 
Slot 3 
Slot 4 
INT – A (A6) 
channel 1 
channel 2 
channel 3 
channel 4 
INT – B (B7) 
channel 2 
channel 3 
channel 4 
channel 1 
INT – C (A7) 
channel 3 
channel 4 
channel 1 
channel 2 
INT – D (B8) 
channel 4 
channel 1 
channel 2 
channel 3 
Highlighted entries refer to master interrupts of the slot module