Fujitsu FLASH-CAN-100 User Manual

Page of 20
Change even page title here 
Chapter 5 Configuration of the Evaluation-Board 
UG-900001-32 
- 12 - 
© Fujitsu Microelectronics Europe GmbH 
5.1  Modifications for use with MB90470 / MB90480 series 
Some modifications have to be done in order to use the FLASH-CAN-100P Board together 
with a MCU of the MB90470 / MB90480 series: 
 
1.  Check that U6 is MAX3232CPE 
2.  Change R6 470 => 390 Ohm. Check that output voltage of U3 is 3.3V (JP2) 
3. Disassemble C10 (100nF) 
4.  Connect J4- Pin 27 to JP10- Pin 2 (SIN) 
5.  Connect J4- Pin 28 to JP9- Pin 2 (SOT) 
6.  Connect J5- Pin 80 to GND (X0A) if no Sub-Clock is used 
Otherwise Sub-Clock crystal Y2 and capacitors C5, C6 has to be assembled 
7.  Remove JP1. Connect JP1- Pin 2 to JP2- Pin 1 
8. Emulator-Settings:  
 
Only MB90470series: 
The MB90470 series normally uses 3V power-supply. However, some Ports (P2, P3, P4 and 
P7) can operate with 5V. In this case Pin 23 (Vcc5) of the microcontroller has to be 
disconnected from Vcc on the FLASH-CAN-100P Board but has to be connected to +5V.  
Cutting a trace near the capacitor CB2 on the bottom layer of the board only can do this. 
 
Caution with the probe-cable: 
The probe-cable MB2132-457 (Yamaichi socket) can NOT be used for dual voltage 
(Vcc3=+3V, Vcc5=+5V), because Pin 23 and Pin 84 (Vcc3 / Vcc5) are shortcut within the 
probe-cable. 
S
1
A
B
C
S
2
A
B
C
ON 
OFF
S
W
1
1
2
3
4
5
6
7
8
check emulator-manual for clock-selection-switch