Connect the Internal Battery
The Back-UPS RS is shipped with one battery wire disconnected. To connect the internal battery, proceed as follows:
Note: Connecting the battery is a safe procedure. However, small sparks may occur during the process. This is normal.
2
1
3
4
Place the unit on its side. Slide
the  battery  compartment  cover
upward and off of the UPS.
Pull the battery partially out of the
chassis,  exposing  the  battery
terminals and wires. 
Connect  the  black  battery  wire  to  the
terminals  as  Ground  (-)  terminal.  Slide
the battery back into the chassis.
Align  the  battery  compartment  cover
with  the  grooves  in  the  Back-UPS  RS.
Slide the cover down until it locks.
Installation
Back-UPS
User’s Manual
990-9217  6/02
RS 500
On  Line  (green)
  -  is  lit  whenever  utility
power  is  powering  the  Battery  Backup
outlets.
Overload  (red)
  -  is  lit  whenever  power
demand  has  exceeded  the  capacity  of  the
Back-UPS RS.
Continuous Tone - this alarm is sounded
whenever the Battery Backup Outlets are
overloaded.
Circuit Breaker - the circuit breaker
button located on the rear panel of the
Back-UPS  RS  will  stick  out  if  an
overload  condition  forces  the  Back-
UPS  RS  to  disconnect  itself  from
utility power. If the button sticks out,
disconnect  non-essential  equipment.
Reset  the  circuit  breaker  by  pushing
the button inward.
Replace Battery (red)
 - is lit whenever
the battery is near the end of its useful life,
or flash if the battery is not connected (see
above). A battery that is near the end of its
useful  life  has  insufficient  run-time  and
should be replaced.
Chirps for 1 Minute Every 5 Hours - this
alarm is sounded whenever the battery has
failed the automatic diagnostic test.
On  Battery  (yellow)
-  is  lit  whenever
the  battery  of  the  Back-UPS  RS  is
powering  equipment  connected  to  the
Battery Backup Outlets.
Four  Beeps  Every  30  Seconds  -  this
alarm is sounded whenever the Back-UPS
is  running  On  Battery.  Consider  saving
work in progress.
Continuous  Beeping  -  this  alarm  is
sounded whenever a low battery condition
is  reached.  Battery  run-time  is  very  low.
Promptly  save  any  work  in  progress  and
exit  all  open  applications.  Shutdown  the
operating system, computer and the Back-
UPS RS.
Status Indicators and Alarms
To Computer
USB Port
RJ-45/USB Cable
to Back-UPS RS
5
Connect USB Cable and Install Software (optional)
If Autoplay is not enabled on the computer, proceed as follows:
1. On  the  computer  desktop  of  the  display,  double-click  on  My
Computer.
2. Double-click  on  the  CD-ROM  drive  icon  and  follow  the  on-
screen instructions.
Follow the
on-screen
instructions.
Data Port
w
 
w
 
w.apc.com
®
There are four status indicators (lights) on the front panel of the Back-UPS RS (On Line, On Battery, Overload, and Replace Battery).
Note: Allow the Back-UPS RS to charge a full eight
hours prior to use.
Press the push-button on the front panel of the Back-
UPS RS.
Observe  that  the  following  events  occur  after
pressing and releasing the push-button:
  • The green On-Line indicator flashes.
  • The  yellow On  Battery  indicator  lights  while
the Self-Test is being performed.
  • When Self-Test  has  successfully  completed,
only the green On Line indicator will be lit.
  • If the internal battery is not connected, (see Step
1 above) the green  On Line indicator will light
and the red Replace Battery indicator will flash.
ON LINE
ON BATTERY
OVERLOAD
REPLACE BATTERY
4
Switch on the
Back-UPS RS
The  rear  panel  of  the  Back-UPS  RS  consists  of  the
following elements:
Battery  Back  Up  Outlets  (qty.  of  3). These outlets
provide  battery  back-up,  surge  protection,  and
Electro-magnetic Interference (EMI) filtering. In case
of  power  outage,  battery  power  is  automatically
provided to these outlets. Power (utility or battery) is
not supplied to these outlets when the Back-UPS RS is
switched Off.  Connect  a  computer,  monitor,  and
external disk or CD-ROM drive to these outlets.
Surge Only Outlet. This outlet is always  On (when
utility power is available) and is not controlled by the
On/Off  switch.  This  outlet  does  not  provide  power
during a power outage. Connect a printer, fax machine
or scanner to this outlet.
Avoid placing the Back-UPS RS in:
  • Direct sunlight
  • Excessive heat
  • Excessive humidity or in contact with fluids of
any type
Plug the Back-UPS RS into a wall outlet, as shown.
  • The Back-UPS RS charges the internal battery
any time it is connected to a wall outlet.
Your computer’s power cord.
The telephone ports provide lightning surge protection
for  any  device  connected  to  the  telephone  line
(computer,  modem,  fax  or  telephone).  The  telephone
ports are compatible with Home Phoneline Networking
Alliance  (HPNA)  and  Digital  Suscriber  Line  (DSL)
standards, as well as all modem data rates. Connect as
shown.
Wall Outlet
Modem/Phone/Fax
1
Placement / Power
3
Connect Phone Lines
2
Connect Equipment
to the Back-UPS RS
to Surge Protection
Back-UPS RS Storage
Before storing, charge the Back-UPS RS for at least
eight  hours.  Store  the  Back-UPS  RS  covered  and
upright  in  a  cool,  dry  location.  During  storage,
recharge the battery in accordance with the following
table:
Please  contact  APC  Online  Technical  Support  to
troubleshoot the unit before returning it to APC.
Storage
Temperature
Recharge
Frenquency
Charging
Duration
-5 to 30
o
C
23 to 86
o
F
Every 6 months
8 Hours
30 to 45
o
C
86 to 113
o
 F
Every 3 months
8 Hours
Order Replacement Battery
The typical battery lifetime is 3-6 years (depending on
the  number  of  discharge  cycles  and  operating
temperature).  A  replacement  battery  can  be  ordered
over  the  phone  from  APC,  or  the  battery  can  be
ordered on-line from the APC web site (see below, a
valid credit card is required).
When  ordering,  please  specify  Battery  Cartridge
RBC2.