Installation and Setup 
(Continued)
ELECTRICAL CONNECTION AND CONTROLS
The electrical control box (with circuit breaker)
and "On/Off" switch are located on the left side of
the machine frame. See Figure 3-1. If desired, for
operator convenience, the "On/Off" switch can be
relocated to the right side of the machine frame.
A standard three-conductor power cord with plug
is provided at the back of the electrical control
box. The receptacle providing this service shall be
properly grounded. Before the power cord is
plugged into a 115 Volt, 60 Hz outlet, verify that
all packaging materials and tools are removed
from the machine. Do not plug electrical cord
into outlet until ready to run machine.
Use of an extension cord is not recommended.
However, if one is needed for temporary use, it
must have a wire size of 1.5 mm diameter
[AWG 16 ], have a maximum length of 30.5 m
[100 ft], and must be properly grounded.
Note: Machines outside the U.S. may be
equipped with 220/240 Volt, 50 Hz systems or
other electrical requirements compatible with
local practice.
To reduce the risk associated with
hazardous voltage:
Position electrical cord away from foot and
vehicle traffic.
WARNING
SPACE REQUIREMENTS
The left side of the machine must be a minimum
of 1.0 m (39.4 inches) from the nearest wall.
The right side of the machine must be a minimum
of 0.7 m (27.6 inches) from the nearest wall.
The machine requires a minimum of 2.7 m (106.3
inches) height.
OPERATOR WORKING POSITION
Figure 2-11 illustrates the correct operator
working position.
Figure 2-11—Operator Working Position