Raritan Computer DKSXII-V2.3.0-0D-E User Manual

Page of 362
 
Chapter 8: Device Management 
 
 
139
 
 
  Autodetect (default option) 
  10 Mbps/Half - Both LEDs blink 
  10 Mbps/Full - Both LEDs blink 
  100 Mbps/Half - Yellow LED blinks 
  100 Mbps/Full - Yellow LED blinks 
  1000 Mbps/Full (gigabit) - Green LED blinks 
  Half-duplex provides for communication in both directions, but 
only one direction at a time (not simultaneously). 
  Full-duplex allows communication in both directions 
simultaneously. 
Note: Occasionally there are problems running at 10 Mbps in either 
half or full duplex. If you are experiencing problems, try another 
speed and duplex setting. 
See 
Network Speed Settings
 (on page 289) for more information. 
3.  Select the Enable Automatic Failover checkbox to allow the KSX II to 
automatically recover its network connection using a second network 
port if the active network port fails. 
Note: Because a failover port is not activated until after a failover has 
actually occurred, Raritan recommends that you not monitor the port 
or monitor it only after a failover occurs. 
When this option is enabled, the following two fields are used: 
  Ping Interval (seconds) - Ping interval determines how often the 
KSX II checks the status of the network path to the designated 
gateway. The default ping interval is 30 seconds. 
  Timeout (seconds) - Timeout determines how long a designated 
gateway remains unreachable via the network connection before 
a fail over occurs. 
Note: The ping interval and timeout can be configured to best meet 
the local network conditions. The timeout should be set to allow for at 
least two or more ping requests to be transmitted and responses 
returned. For example, if a high rate of failover is observed due to 
high network utilization, the timeout should be extended to 3 or 4 
times the ping interval. 
4.  Select the Bandwidth. 
5.  Click OK to apply the LAN settings.