Siemens 6ED1050-1AA00-0BE8 User Manual

Page of 372
LOGO! functions 
 
4.4 Special functions list - SF 
 
LOGO! 
198
 
Manual, 04/2011, A5E03556174-01 
4.4.14 
Stopwatch (0BA7 only) 
Short description 
The stopwatch function counts the elapsed time between a start stopwatch signal and a stop 
stopwatch signal.     
 
Symbol in LOGO! 
Wiring 
Description 
En 
A signal at input En begins counting elapsed time at 
analog output AQ. 
Lap 
A positive edge (0 to 1 transition) at input Lap pauses 
the stopwatch. 
A negative edge (1 to 0 transition) at input Lap 
resumes the stopwatch. 
A signal at input R resets the elapsed time.  
Parameter 
You can set a timebase TB for the stopwatch.  
Possible timebase settings:  
10 ms, s, m, and h 
Retentivity: 
/ = No retentivity 
R = The status is retentive 
$4
6:
(Q
/DS
5
3DU
 
Output AQ 
A signal at input Lap holds the value of AQ until Lap 
is reset to 0. A signal at input R resets the value of 
AQ to 0.  
Parameters TB 
You can set a timebase from the following timebase set: 
●  10 ms (10 milliseconds) 
●  s (seconds) 
●  m (minutes) 
●  h (hours)