Fan modules
7.1.4
Replacing the defective fan module
Figure 50: Identifying and removing a defective fan module
Ê
Identify the defective fan module. The indicator of the defective fan lights up 
Orange, see circle in 
Ê
Have the new fan module ready for the installation.
V
CAUTION!
Never leave the fan module bay empty for more than two minutes 
during operation. Otherwise, excessive temperatures could damage 
system components.
Ê
Press the handle (1) and lift the fan module out of the housing (2).
Ê
Insert the new fan module in the empty bay until it engages.
The new fan module is tested by Server Management. The indicator then 
either does not light at all (fan is OK) or lights up in Orange (fan is not OK).
/