Maintenance Manual
 RX900 
S1
Hard disk and solid state drives
6.2
Replacing the HDD/SSD module
V
CAUTION!
Only remove an HDD/SSD module during operation if the drive is not 
currently being accessed. Observe the indicators for the 
corresponding HDD/SSD modules, see "PRIMERGY RX900 S1 
Server - Operating manual".
Under no circumstances should you remove an HDD/SSD module 
while the system is in operation if you are not sure that the drive is 
operated by a RAID controller and belongs to a disk array that is 
operating in RAID level 1, 1E, 10, 5, 50, 6 or 60.
An HDD/SSD module can only be replaced during operation in 
conjunction with a corresponding RAID configuration.
All HDD/SSD modules (drives) must be uniquely identified so that 
they can be reinstalled in their original mounting locations later. If this 
is not done, existing data can be lost.
6.2.1
Required tools
Starting and completing the task:
key for the rack doors (if applicable)
Replacing the HDD/SSD module: tool-less
Trained personnel