Fujitsu V6.00 User Manual

Page of 174
ServerView Event Manager
 125
Trap overview
5.3.14 PXRE traps (dec.mib)
MIB-OID: 1.3.6.1.4.1.36.2.15.21
This section lists PXRE traps in alphabetical order.
Trap name
 ID
Meaning
Error class
cacheBatteryFailureTrap
7
A controller cache battery 
has failed. Replace cache 
battery or replenish charge.
major
cacheBattery
InformationTrap
9
A controller cache battery 
has 
GOOD
 state.
informational
cacheBatteryLowTrap
8
A controller cache battery 
has 
LOW
 state. Replace 
cache battery or replenish 
charge. 
minor
communication
FailureTrap
12
Communication with the 
subsystem has failed. The 
Possible causes are data 
path interruption, 
communication LUN failure, 
2 or more power supplies 
failed, 2 or more fans failed, 
temperature over limit, both 
controllers failed.
critical
communicationInformatio
nTrap
13
Communication with the 
subsystem has recovered.
informational
controllerFailureTrap
14
The Secondary Controller 
in the subsystem has failed. 
Replace controller. Possible 
causes are PCMCIA 
memory card ejected, 
controller physically 
removed, actual hardware 
failure.
major
controllerInformationTrap 15
The Secondary Controller 
in the subsystem has 
recovered.
informational
Table 37: PXRE traps