Fujitsu V6.00 User Manual

Page of 174
ServerView Event Manager
 127
Trap overview
fanFailureTrap
5
The fan in the specified 
location has failed. Replace 
fan.
major
fanInformationTrap
6
The fan in the specified 
location was recovered.
informational
lunFailureTrap
16
The LUN has failed and is 
off-line. Possible cause is 
too many failed disk drives 
that make up the LUN, the 
OS can no longer 
communicate with the LUN 
for other reasons.
critical
lunInformationTrap
19
A LUN has become optimal 
due to successful 
completion of the 
reconstruction process.
informational
lunReconstructTrap
17
The LUN has started the 
reconstruction process but 
is available for normal use. 
Possible causes are an 
available disk drive was 
created as a spare to be 
inserted into the set, an 
existing spare was 
automatically added to the 
set for reconstruction upon 
failure of a member disk 
device.
minor
lunReducedTrap
18
A LUN has become 
degraded due to a member 
disk device failure. Replace 
the failed disk device; add a 
spare to the system to 
cause a reconstruct. 
major
Trap name
 ID
Meaning
Error class
Table 37: PXRE traps