Fujitsu TX200 S6 User Manual

Page of 126
78
Operating Manual
 TX200 
S6
Starting up and operation
I
If the operating system does not switch the server off automatically, press 
the On/Off button for at least four seconds and/or send a control signal 
for power button override.
Other On/Off options
Besides the On/Off button, the server can be switched ON and OFF in the 
following ways:
Timer-controlled switch-on/off
Using the ServerView Operations Manager or iRMC S2, you can configure 
that the server is switched on/off controlled by timer.
Ring indicator
The server is switched on by an internal or external modem. 
Wake up On LAN (WOL)
The server is switched on by a command via the LAN (Magic Packet
TM
).
After power failure
The server automatically reboots following a power failure (depending on the 
settings in the BIOS or in iRMC S2).
Power button override
The system can be switched off by pressing and holding down the On/Off 
button (for approximately 4 - 5 seconds).
V
CAUTION!
There is a risk that data may be lost.
iRMC S2
iRMC S2 offers various options for switching the server on and off, e.g. via 
the 
Power On Off
 page of the iRMC S2 Web interface.