Fujitsu 2000 SERIES User Manual

Page of 285
CHAPTER 3 Component Configuration and Replacement (Add, Remove) 
3.3 Replacing components 
48 
 
C122-E175-01EN 
 
3.3.1  Replaceable components  
Replaceable components and replacement conditions are listed in the table below. 
TABLE 3.10
 Replaceable components and replacement conditions 
Component name 
AC power off 
(Device stop) 
AC power on 
status All 
partitions off 
status  (hot 
maintenance) 
AC power on 
target  partition 
off  (hot 
maintenance) 
AC power on 
target  partition 
on  ( hot 
maintenance) 
PSU_P/PSU_S 
Replaceable 
Replaceable 
Replaceable (*1)   Replaceable (*1)  
 
FANM 
Replaceable 
Replaceable 
Replaceable (*1)   Replaceable (*1)  
FANU 
Replaceable 
Replaceable 
Replaceable 
Replaceable 
 
FANM 
Replaceable 
Replaceable 
Replaceable 
Replaceable 
SB 
Replaceable 
Replaceable 
Replaceable 
Replaceable (*5)  
 
CPU 
Replaceable 
Replaceable 
Replaceable 
Not replaceable 
DIMM 
Replaceable 
Replaceable 
Replaceable 
Not replaceable 
Mezzanine 
Replaceable 
Replaceable 
Replaceable 
Not replaceable 
 
DIMM 
Replaceable 
Replaceable 
Replaceable 
Not replaceable 
PCI Express card   
Replaceable 
Replaceable 
Replaceable 
Not replaceable 
 
FBU 
Replaceable 
Replaceable 
Replaceable 
Not replaceable 
HDD/SSD 
Replaceable 
Replaceable 
Replaceable 
Replaceable (*2)  
Battery  
Replaceable 
Replaceable 
Replaceable 
Not replaceable 
IOU_1GbE/IOU _10GbE 
Replaceable 
Replaceable 
Replaceable 
Replaceable (*5)  
 
PCI Express card   
Replaceable 
Replaceable 
Replaceable 
Not replaceable 
DU 
Replaceable 
Replaceable 
Replaceable 
Not replaceable 
 
PCI Express card   
Replaceable 
Replaceable 
Replaceable 
Not replaceable 
 
FBU 
Replaceable 
Replaceable 
Replaceable 
Not replaceable 
HDD/SSD 
Replaceable 
Replaceable 
Replaceable 
Replaceable (*2)  
MMB 
Replaceable 
Replaceable (*3)  
Replaceable (*3)   Replaceable (*3)  
OPL 
Replaceable 
Not replaceable 
Not replaceable 
Not replaceable 
MP, PDB 
Replaceable 
Not replaceable 
Not replaceable 
Not replaceable 
PCI_Box  
Replaceable 
Replaceable 
Replaceable 
Not replaceable 
 
IO_PSU 
Replaceable 
Replaceable 
Replaceable (*1)   Replaceable (*1)  
IO_FAN 
Replaceable 
Replaceable 
Replaceable (*1)   Replaceable (*1)  
PEXU 
Replaceable 
Replaceable 
Replaceable 
Not replaceable 
 
PCI Express card 
Replaceable 
Replaceable 
Replaceable 
Replaceable (*4)  
*1: Possible only in configuration. 
*2: Possible only for redundancy configuration with RAID. 
*3: Possible only for MMB duplication configuration. 
*4: PCI hot plug function is required.  Operation by maintenance staff is optional. 
*5: DR function is required. 
3.3.2  Component replacement conditions 
This section describes the replacement conditions of each component. 
PSU 
The PSU unit can be replaced while the system continues operating. PSU replacement in a non-redundant 
configuration requires the system to be stopped.  
FAN 
The FAN unit can be replaced while the system continues operating.  
SB 
If the DR function (SB hot remove and SB hot add) is used, the SB can be replaced even when the partition 
using the SB is powered on. When the DR function is not used, the SB can be replaced if the partition using 
the SB is powered off.  
Remarks  
Since the CPU/Mezzanine/DIMM/PCI Express card /FBU which is mounted on the SB can be replaced after 
removing the SB from the device, the replacement can be done under the same conditions as the SB.  