CHAPTER 3 Component Configuration and Replacement (Add, Remove) 
3.3 Replacing components 
49 
 
C122-E175-01EN 
 
Since there may be a time deviation after the Home SB is replaced, set the time in the operating system 
when the NTP is not used.  
IOU_1GbE/IOU_10GbE 
If the DR function (IOU hot remove and IOU hot add) is used, the IOU_1GbE and IOU_10GbE can be 
replaced even if the partition that uses the IOU_1GbE/IOU_10GbE is powered on. If the DR function is not 
used, then the replacement is possible when the partition that uses the IOU_1GbE/IOU_10GbE is powered 
off. 
DU 
DU can be replaced when the status of the partition that uses the DU to be replaced is powered off.  
MMB 
In a system with two MMBs installed, hot replacement can be used to replace an MMB when the system 
continues operating. Basically, the faulty MMB (Standby MMB) can simply be replaced since a faulty MMB 
would have been switched with a standby MMB. To replace the active MMB, switch it with the standby MMB 
before replacing it. The replacement does not affect control and monitoring in the system. 
3.3.3  Replacement procedures in hot maintenance  
This section describes the procedures before and after replacement in hot maintenance.  
Procedure before replacement 
See ‘7.1.2 Power off of Partitions’ in “PRIMEQUEST 2000 series Installation Manual” (C122-E174) and stop 
the relevant partition. 
Procedure after replacement 
See ‘7.1.1 Power on of partitions’ in “PRIMEQUEST 2000 series Installation Manual” (C122-E174) stop the 
relevant partition following the 
3.3.4  Replacement procedures in cold maintenance 
This section describes the procedures before and after replacement in cold maintenance. 
Procedure before replacement 
Stop all the partitions. 
Procedure after replacement 
Start the relevant partition.
 
3.3.5  Replacing the battery backup unit of the uninterrupted power 
supply unit (UPS)  
This section describes the procedure for replacing the battery backup unit of the UPS. The UPS battery is 
regularly replaced and the life cycle is monitored by the RAS support service. 
 
RAS support service monitors the life cycle and notifies the message as shown below.  
TABLE 3.11
 
Replacement notification messages
 RAS support service (UPS) 
 
Start time for notifying messages for advance 
notification of replacement 
Replacement message 
notification time
 
About 1 year and 9 months from the start of use or 
replacement of the battery  
After about 2 years 
 
For details on the
 RAS support service, see ‘RAS Support Service User Guide’. 
3.3.6  Replacing the PCI SSD card 
This section describes the procedure for replacing the PCI SSD card.  
Note  
The PCI SSD card does not support hot replacement. Stop the partition before replacing.