This section describes the connection specifications of Input power of the base cabinet or PCI_Box of 
PRIMEQUEST 2000 series. 
2.4.1  Input Power Connection Specifications (Base Cabinet) 
Following table shows the input power connection specifications of the main unit. 
TABLE 2.2 Power Cable Specifications (Base Cabinet) 
Destination 
Plug format 
Remarks 
100 V 
Parallel 2-pole plug 
with earthing-contact 
“NEMA standard 5-
15P” 
Connection at wall-mount power distribution 
Recipient power distribution 
format 
 
Power distribution “NEMA 
standard  5-15R” for parallel 
2-pole plug with earthing - 
contact (125V 15A)  
200 V 
IEC60320-C20 type 
Connection at power distribution box 
Recipient outlet format 
 
IEC60320-C19type 
Remarks 
Power cable supplied with the device and power cord supplied with the option part, are used for the 
power cable which is connected to the device. However, the supplied power cable is not used for the 
other products. 
Power distribution box which is suitable to recipient power distribution format is used 
2.4.2  Input Power Supply Connection Specifications (PCI_Box) 
Following table shows the input power supply connection specifications of PCI_Box. 
 
TABLE 2.3 Power Cable Specification (PCI_Box) 
Destination 
Plug format 
Remarks 
100V 
Parallel 2-pole plug with 
earthing-contact 
“NEMA standard 5-15P” 
Connection at wall-mount power distribution 
Connection at power 
distribution box 
 
Power distribution 
“NEMA standard  5-
15R” for parallel 2-
pole plug with 
earthing- contact 
(125V 15A)  
200V 
IEC60320-C14 type 
Connection at power distribution box 
Recipient outlet 
format 
 
IEC60320-C13 type 
Remarks 
Power cable supplied with the device and power cord supplied with the option part, are used for the 
power cable which is connected to the device. However, the supplied power cable is not used for the 
other products. 
Power distribution box which is suitable to recipient power distribution format is used