Nortel Networks 1000M User Manual

Page of 458
 Installing a Signaling Server
 Page 447 of 456
Communication Server 1000M and Meridian 1
Large System Installation and Commissioning
Verifying a successful configuration
To ensure that the Signaling Server Ethernet connections (for the ELAN and 
TLAN subnets) are configured correctly, perform a ping test to one or more 
of the other devices connected to the network, particularly the Call Server.
Procedure 82
Verifying the Signaling Server Ethernet connection
1
Log in to the Signaling Server, using Procedure 81 on 
2
Ping the IP address of the Signaling Server. Enter the command:
ping x.x.x.x
Where x.x.x.x is the Signaling Server ELAN network interface IP 
address.
3
Ping the IP address of the Call Server. Enter the command:
ping x.x.x.x,3
Where x.x.x.x is the Call Server ELAN network interface IP address.
4
If desired, repeat step 3 for other devices connected to the network.
End of Procedure
Testing the Leader Signaling Server
Configure two IP Phones to register to the Signaling Server on its temporary 
node. These IP Phones must be provisioned on the Call Server. Refer to 
Communication Server 1000E: Installation and Commissioning  
(NN43041-310), Communication Server 1000M and Meridian 1: 
Large System Installation and Commissioning 
(NN43021-310), or 
Communication Server 1000M and Meridian 1: Small System Installation 
and Configuration 
(NN43011-310) for the procedure appropriate to the 
system. After provisioning, the telephones can call each other.