Lucent Technologies 555-233-115 User Manual

Page of 502
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Upgrading R5si/R6si to R8r EPN and Adding Memory 
3-52
Release 5/6si to Release 8r 
3
Install Cable Clamps
1. Behind the cabinets, using screws provided, install 2 cable clamps on 
each ground plate. See 
. These clamps hold the port cables.
Figure 3-19.
Location of Ground Plate and Cable Clamps
Retranslate Port Circuits
If port circuit packs in the Release 5/6si control cabinet were relocated in order 
to:
Use a TN748B to replace the tone detector circuits on a TN756
Put a critical port circuit pack, requiring longer nominal battery holdover (a 
DS1 or an Announcement circuit pack), in a port slot
Put a TN570 EI circuit pack in port slot 1 or port slot 2 (for a second EPN)
Put a TN755B power supply in port slots 16 and 17
1. Verify the port circuit packs were retranslated during the off-site software 
upgrade. If not, retranslate them now. Refer to 
DEFINITY Enterprise 
Communications Server Release 8 Administrator’s Guide.
Figure Notes
1. Port Cabinet 
2. Control Cabinet
3. Cable Clamps
4. Ground Plate
cadf008 CJL 103096