Multicarrier G2 Universal Module to R8r EPN 
5-4
Read This First 
5
Earlier versions of lightwave transceivers include the 4-series transceivers (4A 
through 4F). These transceivers support fiber connections up to 7,000 feet (2134 
m) apart; whereas the 9823A supports connections up to 5,000 feet (1524 m), 
and the 9823B supports connections up to 25,000 feet (7620 m). A single mode 
fiber transceiver (300A) supports distances of up to 115,000 feet (21.7 miles, 
35 km). If the site inspection reveals that the older 4-series transceivers reside in 
the system, Order the correct transceivers according to a separate PEC.
NOTE:
Using the 300A may require 5 or 10 dB attenuators. Contact your Lucent 
Technologies representative for more information.
NOTE:
The 9823A transceiver is 
not a direct replacement for the 4-series 
transceiver (since a pair of 9823A transceivers 
cannot replace a pair of 
4-series transceivers supporting a connection of between 5,000 feet 
(1524 m) and 7,000 feet (2134 m)).
Power and Ground
The new multicarrier PPN cabinet or any EPN cabinet added for the upgrade can 
be either AC- or DC-powered. If an added cabinet is powered differently from the 
existing cabinets, the existing cabinets do not have to be converted since mixed 
power configurations are allowed. However, the system’s power and grounding 
must be modified so that the AC-powered cabinets are grounded to the same 
single-point ground point as the DC-powered cabinets.
If a new AC-powered cabinet is to be added, provide a separate AC receptacle 
to support the new cabinet. This AC receptacle must not be shared with any 
other equipment and must not be controlled by a wall switch. For the 
convenience and safety of equipment-room personnel, the receptacle should not 
be located under the MDF.
NOTE:
The new AC-powered PPN for a Release 8 upgrade has different power 
requirements than the G2 system. Refer to the 
DEFINITY Enterprise 
Communications Server Release 8 System Description Pocket Reference 
for information. 
DC Isolator
Each device connected to a DC-powered cabinet, from the asynchronous EIA 
RS-232 interface, requires a 116A isolator. Insert the isolator at the RS-232 
interface between the device and the interface connector to isolate ground 
between the system and external adjuncts.