Lucent Technologies 555-233-115 User Manual

Page of 502
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN 
5-17
Standard Reliability 
5
Check Link Status
1. Type display communication-interface links and press 
Enter
. Write down 
all enabled links.
2. Type status link 
number and press 
Enter
. Repeat this step for all links.
3. Write down which links are in service.
Disable TTI
!
CAUTION:
If you do not disable the TTI, the translations can be corrupted.
1. Make sure the ISDN is in service. If not, attempt to busy out and release 
the ISDN D-channel/link. This will bring the ISDN trunks back into service.
2. Type change system-parameters features and press 
Enter.
 Use screen 2 
to disable Terminal Translation Initialization (TTI) by changing the value to 
n.
Power Down G2 System
1. At the common control’s power distribution unit, set the main circuit 
breaker to OFF.
2. At the universal module’s power distribution unit, set the main circuit 
breaker to OFF.
Install Power-Failure Transfer Ground Wire
!
CAUTION:
To avoid contaminating single-point ground, do not connect the ground wire 
while the system is powered up.
1. Connect a 10 AWG (#25) (2.6 mm
2
) wire to pin 49 of the connecting block 
or to pin 49 of the CAP (cable access panel) on the power-failure transfer 
panel.
2. Route the opposite end of the wire to an approved ground and connect.