5
Unpack and Inspect Expansion Control Carrier
1. Inspect the new J58890AF Expansion Control Carrier for any damage. 
Also verify that the backplane pins are not bent.
2. Place the expansion control carrier on the floor so that the rear of the 
carrier faces up.
3. Install the CFY1 current limiter (CURL) on the “A” carrier to the pin-field 
block labeled “CURL” Install the CURL with the components on the left.
4. At the rear connector panel, determine which connectors will have a cable 
attached, and install a 4B cable retainer on each of these connectors.
Install New Expansion Control Carrier A
1. Install the carrier in position “A” by aligning the plastic alignment tips on 
the top rear of the carrier with the screw holes in the cabinet. These 
alignment tips support the carrier while installing the screws. Ensure that 
the power cords are properly placed in the slots at the sides of the carrier.
2. Fasten the carrier into position with 4 self-tapping screws saved from the 
removal of the old carrier.
NOTE:
Carefully realign the threads on the self-tapping screws by turning 
them counterclockwise 1 turn before tightening them to avoid 
stripping the threads out of the framework.
3. Connect the “P2” and “P1” cables to the “A” carrier. Se
. Snap 
the connector lock into place to ensure the connection is properly made.
4. Connect the 8 ground straps from the “C” carrier to the new “A” carrier. 
See 
5. Connect the 8 ground straps from the “D” carrier to the new “A” carrier. 
6. For AC-powered systems, install the 2 new ground straps. One strap 
connects ground point “1” to the “A” carrier frame (right side), and the 
other connects ground point “8” to the “A” carrier frame (left side).
NOTE:
DC-powered systems do not use these carrier ground straps.
7. Connect the remaining end of the TDM/LAN cable (between the “A” and 
“D” carriers) to the pin-field block marked “TDM” on the right side of the 
“A” carrier. See 
 and 
8. Connect the remaining end of the TDM/LAN cable (between the “A” and 
“C” carriers) to the pin-field block marked “TDM” on the left side of the “A” 