Lucent Technologies 555-233-115 User Manual

Page of 502
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Multicarrier G2 Universal Module to R8r EPN 
5-25
Standard Reliability 
5
9. On port carrier J58890BB-1, connect the TDM cable or TDM terminator to 
Slot 02. On port carriers J58890BB-2 and J58890BB-3, connect the TDM 
cables to Slot 01.
10. Install the front trim plate on the “A” carrier. Install the fan trim plate.
11. Install the power units (removed from G2 universal module) into the “A” 
carrier. Do not interchange the physical locations of the units. The 
631AR1, 631WA1, 631DA1, or 644A install in the left side, while the 
631BR1, 631WB1, 631DB1, or 645B install in the right side.
NOTE:
In most cases, the new Release 8 carrier will contain the same power 
supplies as in the existing system. However, a Release 8 carrier may 
contain a 649A Power Unit. If so, re-use the power units from the G2 
power module.
12. If the expansion control carrier contains a 631BR1, 631WB1, or 645B 
power unit, install the previously removed TN736 power unit in port slots 
“18” and “19” of the carrier (adjacent to the 631BR1, 631WB1, or 645B). If 
the system is equipped for neon message waiting, a TN752 or TN755 
power unit must be used.
NOTE:
The TN736 is not required when the 631DB1 or 645B power unit is 
used in the J58890AF-1 expansion control carrier or the J58890BB-2 
or J58890BB-3 port carriers. It is required in the J58890BB-1 port 
carrier, regardless of which 631 power unit is provided. Use the 
TN752 or TN755 if the system contains neon message waiting.
13. Connect the white power cords to the power units.
Table 5-7.
TDM/LAN Connections
"J" Number
Carrier Type
LHS Slot
RHS Slot
J58890BB-1
Port
21
02
J58890BB-2
Port
21
01
J58890BB-3
Port
21
01
J58890AF
EPN Control “A”
21
02