Lucent Technologies 555-233-115 User Manual

Page of 502
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Upgrading G3rV2, V3, V4 to R8r and Adding Memory 
1-2
Read This First 
1
Read This First
Service Interruption
The upgrade process requires 2 non–call-preserving service interruptions in a 
standard reliability system and must be closely coordinated with the customer 
and the local account team.
Call Management System (CMS)
The CMS link is dropped and restarted during the upgrade. This causes CMS 
data to be lost. This data loss can be minimized if the upgrade is performed just 
after the last CMS measurement interval.
All measurement data is lost during the upgrade (including BCMS). If needed, 
the reports may be printed before the upgrade begins.
CMS could abort the processing of a call if a measured trunk that was part of the 
conference dropped off the call before the end of the call. Customers 
experiencing this symptom and who are running R3V4 CMS should update to 
r3v4ao.e or higher.
Software Compatibility and Translation Errors
Before starting the upgrade, always check the 
Software Release Letter that 
accompanies the system removable media. Translation corruption will occur if 
incompatible software is loaded. 
After loading the new software, check for translation errors. To do this, log off and 
then log back in. Check for a “Translation Corruption Detected” message before 
proceeding with the upgrade.
If the message indicates errors, refer to 
. Do not continue with the upgrade 
until the errors are corrected. 
Usable Circuit Packs
Every circuit pack used in the Release 8 system must conform to the minimum 
usable vintage requirements for that system. At a presale site inspection, the 
remediation process checks the vintages of existing circuit packs to be reused in 
the Release 8 system. Replace all unusable vintage circuit packs with current 
vintages.
Refer to 
Technical Quarterly, Reference Guide for Circuit Pack Vintages, Change 
Notices, and to the Software Release Letter for information about usable circuit 
pack vintages. For information about usable vintages of non-U.S. circuit packs, 
refer to the ITAC Tech Alert from your regional distributor.