Lucent Technologies 555-233-115 User Manual

Page of 502
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-44
Add DCS Interface 
6
Enter Added Translations
1. Get the DOSS order number of the upgrade. Call the regional CSA to 
perform the steps in this section.
2. To enable DCS, set the 
DCS
 field on the System Parameters-Customer 
Options screen to y.
3. Administer the other required translation data using the forms listed under 
Distributed Communications System (DCS) in 
DEFINITY Communications 
System Administration for Network Connectivity.
Save Translations
1. If the system is high- or critical-reliability, type status spe and press 
Enter 
to verify that the standby SPE is refreshed and that the standby disk is in 
service.
2. Enter save translation [spe-a or both] disk and press 
Enter
. This 
command instructs the system to take all translation information in 
memory and write it to the disk(s).
Table 6-3.
TN799 Pinout
Backplane Pin
25-Pair Wire Color
Lead Name
Peripheral 
Connector Pin
103
White/Orange
TD+
27
003
Orange/White
TD-
2
104
White/Green
RD+
28
004
Green/White
RD-
3