April 2000
Adding or Removing Cabinet Hardware 
6-45
Add IP Interface Assembly 
6
Add IP Interface Assembly
DEFINITY ECS IP Solutions allows you to send voice and fax from the DEFINITY 
ECS through an Internet protocol (IP) network to other DEFINITY ECSs having 
this feature or to other H.323 V2 compliant endpoints. It is implemented using the 
TN802/B IP Interface, which is a Windows NT server residing on the IP Interface 
Assembly inside the DEFINITY ECS.
The IP Interface is an assembly composed of a TN802B circuit board, a 
processor card, and DSP resource card. For ordering purposes, the assembly is 
identified as a J58890MA-1 L30, but for simplicity, we refer to it in this book as the 
TN802B IP Interface.
The TN802B IP Interface operates in two modes: IP Trunk, available with Release 
7 or later, and Media Processor (MedPro), available with Release 8. The IP Trunk 
mode is Internet Telephone Server—Enterprise (ITS-E) compatible, and the 
MedPro mode is H.323 V2 compatible. The TN802B IP Interface is backwards 
compatible and defaults to IP Trunk mode.You must administer it to use it in 
MedPro mode.
For more information on the IP Interface capabilities and limitations, refer to the 
DEFINITY Enterprise Communications Server Release 8 Overview.
The following sections describe the process for
!
WARNING:
When connected remotely via pcANYWHERE, only use the pcANYWHERE 
Restart Host Computer button on the toolbar to restart Windows NT.
Installing in Media Processor Mode
To operate in MedPro mode, you must install the TN802B IP Interface and, if the 
system does not have one, you must also install and administer a TN799B C-LAN 
circuit pack. For C-LAN administration, refer to 
DEFINITY Enterprise 
Communications Server Administration for Network Connectivity.
If you have existing TN802 IP Interface circuit packs, you can upgrade them 
either by replacing the circuit pack with a TN802B or by downloading the 
TN802B firmware onto the circuit packs (see 
).