Adding or Removing Cabinet Hardware 
6-72
Add IP Interface Assembly 
6
3. At the command prompt, type ping 
nnn.nnn.nnn.nnn (which is the IP 
address of your gateway). 
If everything is configured correctly, the system responds with the 
following message:
Reply from nnn.nnn.nnn.nnn: bytes=32 time<##ms 
TTL=###
If no response, verify the IP address information and check the 
connectivity, including the cabling.
I f all else fails, click on Start > Settings > Control Panel > 
Network
. Select the Adapters tab and highlight the [2] DEC 
adapter.
Click Properties > Change
From the Duplex Mode dropdown menu, select a setting that 
matches the switch/hub that the TN802B connects to. For example, 
10BaseT Full Duplex or 10BaseT No Link Test
4. At the command prompt, type ping 
nnn.nnn.nnn.nnn (which is the IP 
address of another external computer beyond the gateway). 
If you have connectivity, the system responds with the following 
message:
Reply from nnn.nnn.nnn.nnn: bytes=32 time<##ms 
TTL=###
If no response, verify the IP address information and check the 
connectivity, including the cabling. Consult your IP network 
administrator.
5. Type exit and press 
Enter
.
Test the IP Interface Onboard LAN Connections
To test the onboard LAN connections, ping the IP Interface server and the 
processor on the TN802B IP Interface.
1. Click Start > Programs > Command Prompt.
2. Type ping 
192.11.13.9 (which is the IP address of the internal IP Interface 
server). 
If everything is configured correctly, the system responds with the 
following message:
Reply from 192.11.13.9: bytes=32 time<##ms TTL=###
If no response, verify the IP address information and check the 
connectivity, including the cabling.