DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-73
Add IP Interface Assembly 
6
3. At the command prompt, type ping 
192.11.13.8 (which is the IP address of 
the internal processor). 
If you have connectivity, the system responds with the following 
message:
Reply from 192.11.13.8: bytes=32 time<##ms TTL=###
If no response, verify the IP settings for Adapter [1].
4. Type exit and press 
Enter
.
The TN802B IP Interface is now installed in the DEFINITY carrier and connected 
to the IP network. You can now use the Configuration Manager software 
(preinstalled on the TN802B hard disk) and DEFINITY ECS switch administration 
to administer connections to other IP Trunk and ITS-E equipment. 
Upgrading a TN802 V3 (or later) to a TN802B 
(MedPro mode)
If you have a TN802 V3 (or later) IP Interface, you must either replace it with a 
TN802B circuit pack or upgrade the existing TN802 circuit pack to operate in 
MedPro mode. Also, to operate in the MedPro mode, the DEFINITY ECS switch 
must be Release 8 or later.
NOTE:
The TN802 IP Interface must be V3 or later to upgrade to TN802B.
To upgrade the TN802 to a TN802B, you need the following hardware: 
Monitor, keyboard, and mouse to access the IP Interface’s Windows NT 
environment or pcANYWHERE software.
10-Mbyte SanDisk PCMCIA flashcard loaded with the MedPro 
NT Application Install Wizard
TN802B label
The upgrade adds or modifies the following directories or files on your 
computer’s hard drive:
c:\dolan\*
c:\mapd\dnld\medpro.img
c:\mapd\dnld\tmp.img