DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-90
Add a Control Carrier (Add Duplication) 
6
10. Connect the loose end of the TDM/LAN cable (between the “C” and “B” 
carriers) to the pin-field block marked “TDM/LAN” on the right side of the 
“B” carrier (See 
 and 
). The other end remained 
connected to the “C” carrier when the old carrier was removed.
11. Connect the loose end of the TDM/LAN cable (between the “A” and “B” 
carriers) to the pin-field block marked “TDM/LAN” on the left side of the 
“B” carrier (See 
 and 
). The other end remained 
connected to the “A” carrier when the old carrier was removed.
12. Install the alarm duplication cable (H600-198 G1) between carriers “B” 
and “A.” Connect the cable to the “ICCA” pin-field block (to the right of the 
pin-field block for slot “00”) of both carriers. Se
Connect the 
“UAK” (upper) connector to carrier “B,” and connect the “LAK” (lower) 
connector to carrier “A.”
!
CAUTION:
While installing the ICC cable connectors, be careful not to bend any 
backplane pins. Double check each connection to verify that the 
pins are straight.
NOTE:
With a connector in each hand, flex the wires within the cable’s 
sheath to form a usable C-shaped cable.
13. Install the ICCC cable (H600-182 G1) between carriers “B” and “A.” 
Connect the cable to the “ICCC” pin-field block (behind slot “01”) of both 
carriers. See 
14. Install the duplication cable (WP91954 L1) between carriers “B” and “A.” 
Connect the cable to the “ICCD” pin-field block (behind slot “02”) of both 
carriers. See 
NOTE:
The duplication cable’s connectors are keyed to ensure proper 
positioning on the pin-field block.
Table 6-8.
TDM/LAN Connections
“J” Number
Carrier Type
LHS Slot
RHS Slot
J58890BB L1
Port
21
02
J58890BB L2
Port
21
01
J58890BB L3
Port
21
01
J58890AP
Control
21
02