Lucent Technologies 555-233-115 User Manual

Page of 502
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-96
Add a Switch Node Carrier (Standard Reliability) 
6
Shut Down DEFINITY AUDIX System
1. Shut down the AUDIX assembly and allow the disk to completely spin 
down. Refer to 
.
!
WARNING:
Neglecting to shut down an AUDIX assembly before powering down 
the system cabinet where it resides can damage the AUDIX disk.
2. Unseat the AUDIX assembly from its backplane connectors.
Power Down Cabinet
1. At the cabinet that is receiving the new switch node carrier, set the main 
circuit breaker to OFF.
Remove Doors 
1. Remove the front and rear doors from the cabinet where the switch node 
carrier will be installed.
Disconnect Ground Cables
Skip these steps if a switch node carrier is being added to an empty carrier 
position.
1. Label the ground cables associated with the port carrier to be removed.
2. Disconnect the ground cables from the top of the port carrier to be 
removed. Allow the cables to hang down for now.
Remove Circuit Packs from Port Carrier D
Skip these steps if a switch node carrier is being added to an empty carrier 
position.
1. To ensure that circuit packs and power units in the “D” carrier are properly 
replaced, label each component with its slot number.
2. Disconnect the power cords from the power units in the “D” carrier.
3. Remove all circuit packs and power units from carrier “D.” Store the circuit 
packs in static-proof packaging.
4. Remove the circuit pack blanks from slots that do not contain circuit 
packs.
5. Remove the front trim plate from the “D” carrier by pulling it straight off.