Lucent Technologies 555-233-115 User Manual

Page of 502
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Upgrading G3rV2, V3, V4 to R8r and Adding Memory 
1-10
Upgrade the software and hardware 
1
Check TTI Status 
1. Type status TTI and press 
Enter
. Wait until the 
Percent Complete
 field 
shows 100%.
Busyout MMI Circuit Packs (H/C only)
!
CAUTION:
Multimedia-to-voice station calls are not preserved on an upgrade. Failure to busy-out 
the TN787 Multimedia Interface (MMI) circuit packs results in unusable TN787 and 
TN788 Multimedia Voice Conditioner ports.
1. Type display system-parameters customer-options and press 
Enter
. On 
screen 2 under the Multimedia Call Handling (MMCH) options, check the 
Basic
 and 
Enhanced
 fields. 
2. If either the 
Basic
 or 
Enhanced
 field is y, type list configuration all and 
press 
Enter 
to locate all MMI (TN787) circuit packs.
3. If there are MMI circuit packs, type busyout board 
cabinet carrier slot 
and press 
Enter 
to remove the circuit packs from service.
Lock the active SPE (H/C only)
1. Type status spe and press 
Enter
 to determine which control carrier is 
active or observe the control carrier LEDs.
NOTE:
For high or critical reliability systems, we recommend that you 
replace the circuit packs in the standby carrier first.
!
CAUTION:
When replacing any hardware, be sure to ground yourself against 
electrostatic discharge (ESD) by wearing a grounded wrist strap.
2. Move the SPE-SELECT switches on both Duplication Interface (DUPINT) 
circuit packs, 