Adding or Removing Cabinet Hardware 
6-132
Add MCC Port Carriers 
6
Power Up MCC Port Network
1. At the MCC port network, set the main circuit breaker to ON.
2. The system performs a level 4 rebooting process, loading the system 
program and default translations from the disk. Rebooting takes 5 to 11 
minutes.
3. Refer to “Initialization and Recovery” and “LED Interpretation” chapters in 
DEFINITY Enterprise Communications Server Release 8 Maintenance for 
R8r, for circuit pack LED indications and management terminal displays 
that occur during system reboot.
4. After the system reboot is finished and all trouble cleared, verify that the 
EMERGENCY TRANSFER CONTROL switch is set to AUTO. This restores 
the system to the normal operating mode.
Restart DEFINITY LAN Gateway System
1. Log onto the DEFINITY LAN Gateway. 
2. When the main menu appears, select 
Maintenance.
3. Select 
Reset System from the Maintenance menu.
4. Select 
Restart System from the Reset System menu.
Enter Added Translations
1. Enter added translation data as applicable using 
DEFINITY Enterprise 
Communications Server Release 8 Administrator’s Guide.
Resolve Alarms and Enable Alarm Origination
1. Examine the alarm log. Resolve any alarms using 
DEFINITY Enterprise 
Communications Server Release 8 Maintenance for R8r.
2. If the 
Alarm Origination Activated
 field administration is already 
set to y, be sure to enable Alarm Origination. Otherwise you do not need to 
enable Alarm Origination (proceed to the next section).
3. Type change system-parameters maintenance and press 
Enter
.
The 
Alarm Origination Activated
 field was changed to 
Alarm 
Origination to OSS Numbers
 to support more than 1 OSS.