Lucent Technologies 555-233-115 User Manual

Page of 502
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-133
Add MCC Port Carriers 
6
4. Type first-only in this field to enable Alarm Origination (to the first OSS, 
which should be INADS).
Be sure to type y in both 
Cleared Alarm Notification
 and 
Restart 
Notification
 fields. Press 
Enter
.
NOTE:
The INADS Database Administrator enables Alarm Origination as 
part of the registration process.
!
CAUTION:
If you do not enable Alarm Origination when the customer has 
purchased a services contract, the switch will not report any alarm to 
the TSC automatically, causing the TSC to be unable to fulfill the 
services contract.
Save Translations
1. If the system is high- or critical-reliability, type status spe and press 
Enter 
to verify that the standby SPE is refreshed and that the standby disk is in 
service.
2. Type save translation [spe-a or both] disk and press 
Enter
. This 
command instructs the system to take all translation information in 
memory and write it to the disk(s).
3. If the MCC port network contains a TN750 Announcement circuit pack, 
type list configuration software-version and press 
Enter
.
If screen 2 shows that recorded announcements were saved, these 
announcements can be restored using the restore announcements 
command. Type restore announcements and press 
Enter
.
4. Type backup disk [spe-a or both] and press 
Enter
. This command 
instructs the system to backup the current information on disk to the 
removable media.