DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Fiber Link Administration 
A-5
Administer Fiber Links 
A
Administer Fiber Links on Duplex Systems 
All non-duplicated Switch Node Interfaces to Switch Node Interface fiber links 
are automatically duplicated. When PNC Duplication is enabled on the 
System-Parameters Customer-Options form, the following administration forms 
change:
Cabinet Form 
 Additional fields appear to allow administration of switch 
nodes to A-PNC and B-PNC sides of the CSS. The B-PNC is the 
duplicated hardware for the A-PNC. Either the A-PNC or the B-PNC can 
provide full customized service. B-PNC cannot be used in a simplex PNC 
configuration. Pairing of switch nodes is also defined here.
Fiber Link Administration Form 
 Additional fields appear to allow 
administration of fiber links on the B-PNC side of the CSS. If an endpoint 
on the A-PNC side is administered as an SNI, its corresponding endpoint 
on the B-PNC side is determined (if switch nodes are paired in the cabinet 
form prior to this administration) and displayed. However, administration 
of the duplicate B-PNC link is not enforced until duplication is in full 
operation.
Duplication-Related System-Parameters Form 
 An additional field 
appears to enable operation of PNC duplication.
1. Type change system-parameters customer-options and press 
Enter
. On 
Page 2 of the form, set the 
PNC Duplication?
 field to y. Press 
Enter
.
2. Type change system-parameters duplication and press 
Enter
. Change 
the 
Enable operation of PNC duplication?
 field to y. Press 
Enter
3. Type status pnc and press 
Enter
. Verify the 
Duplicated ?
 field is yes.
4. Type list fiber and press 
Enter
. All administered fiber connections display. 
5. If a previously used fiber link is to be reused, type add fiber <number
and press 
Enter
. If this is a new fiber link, type add fiber next and press 
Enter
6. The Fiber Link Administration form appears. On Page 1 of the form:
a. Enter the 
Board Location: 
for Endpoint-1 and Endpoint-2. This 
is the cabinet, carrier, and slot that identifies the physical location 
of an SNI or EI circuit pack that is the first endpoint of the fiber link. 
Repeat for the remaining endpoints.
b. The 
Board Type
 field is display only and shows the type of circuit 
pack in Endpoint-1.
c. In the 
DS1CONV Board Location
: field, enter the cabinet, carrier, 
and slot that identifies the physical location of DS1 Converter circuit 
pack in the first endpoint of the duplicate fiber link. Endpoint-1’s 
duplicate along with Endpoint-2’s duplicate make up the duplicate 
fiber link called the B-PNC link.