Lucent Technologies 555-233-115 User Manual

Page of 502
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Upgrading G3rV2, V3, V4 to R8r and Adding Memory 
1-17
Upgrade the software and hardware 
1
Upgrade Software 
This command copies the software from the removable media to the system disk 
and takes about 15 minutes to complete. 
For standard reliability:
!
CAUTION:
All calls are dropped—this is a service interruption.
1. Type upgrade software G3V8r.xx.x.xxx.x (entire alphanumeric string of 
new software version) and press 
Enter
. At the prompt, press 
Enter
 to save 
translations.
For high or critical reliability:
1. Type upgrade software G3V8r.xx.x.xxx.x no-calls (entire alphanumeric 
string of new software version) and press 
Enter
. At the prompt, press 
Enter
 
to save translations and attempt to preserve calls across the interchange.
For all reliabilities:
2. After the system resets, log in as craft
3. Check for the 
Translation Corruption Detected
 message before 
proceeding with the upgrade. If corruption is detected, refer to 
 in 
 
to correct the problem. 
!
CAUTION:
Do not continue with the upgrade until the translations errors are 
corrected. 
Reset SPE status (H/C only)
1. Type status SPE and press 
Enter
. Wait until the 
Standby Handshake
 
field displays up, which takes about 3 minutes.
2. Type reset spe-standby 4 and press 
Enter
.
NOTE:
You can continue the process while the SPE is resetting.
List Configuration Control 
1. Type list configuration control and press 
Enter 
to verify the system 
recognizes the third TN1650B Memory circuit pack.