Lucent Technologies 555-233-115 User Manual

Page of 502
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Troubleshooting  an Upgrade 
B-4
New for Release 8 
B
Troubleshooting details for the Mass Storage System may be found under the 
R-MEDIA maintenance object in Chapter 9, Maintenance Object Repair 
Procedures, of the Release 8.2, Maintenance for R8r manual. Additional related 
maintenance objects associated with the Mass Storage System include 
STO-DATADISK, and H-ADAPTR.
Figure B-1.
TN2211 faceplate
The system is usually booted from the boot image stored on disk. The save 
translation
 and save announcements commands save to disk the 
memory-resident translation data and TN750-resident announcement data, 
respectively. The backup disk command copies data from the disk to the 
removable media for backup storage. The restore disk command copies data 
from the removable media back to disk. All MSS components reside in the SPE, 
or PPN control carrier (carrier A for a simplex SPE, carriers A and B for a 
duplicated SPE).
The removable media circuit pack contains SCSI bus terminators, a -48V to +12V 
power converter, an industry standard SCSI-based removable media drive, and 
interface circuitry to the private bus to control the LEDs, detect the presence of 
the circuit pack, and identify the vintage of the hardware.
Red
Green
Yellow
fpdf2211 KLC 010600
TN2211 OPTICAL DRIVE