Troubleshooting  an Upgrade 
B-6
New for Release 8 
B
Control LAN (C-LAN)
The TN799 Control LAN (C-LAN) packet port circuit pack provides TCP/IP 
connection to adjuncts applications such as CMS, Intuity, and DCS Networking. 
The C-LAN circuit pack has 1 10baseT Ethernet connection and up to 16 DS0 
physical interfaces for PPP connections. Putting multiple C-LAN circuit packs into 
a -system gives additional TCP/IP capacity. In addition to the TCP/IP functionality, 
CLAN extends the ISDN capabilities for csi models by providing Packet bus 
access.
A remote socket control link (RSCL) links the C-LAN and the SPE to pass call 
control and other management information. Since one link serves all the ports on 
the circuit pack, maintenance of the RSCL is part of the C-LAN circuit pack 
maintenance.
The C-LAN TN799 circuit pack combines the functions of the PGATE and PI 
circuit packs into one circuit pack. The PGATE or PI can be used with the C-LAN 
to create an X.25-to-TCP/IP bridge for adjunct and DCS connectivity.
Maintenance objects associated under the Control LAN area include CLAN-BD 
(Control LAN Circuit Pack), ETH-PT (Control LAN Ethernet), and PPP-PT (Control 
LAN Packet/Port).
System Links (SYS-LINK)
System Links are packet links that originate at the Packet Interface board and 
traverse various hardware components to specific endpoints. The hardware 
components involved on the forward and reverse routes can be different, 
depending upon the configuration and switch administration. Various types of 
links are defined by their endpoints:
EAL
Expansion Archangel Link terminating at an Expansion Interface board. 
This link carries CCMS messages.
INL
Indirect Neighbor Link terminating at a Switch Node Interface board
PACL
PNC ATM Control Link terminating at a PNC ATM EI board. This link carries 
ATM signaling commands from CaPro to the remote TN2238 (ATM-EI) 
boards.
PGC
Packet Gateway Call-Control Link terminating at a Packet Gateway board
PRI
ISDN PRI D-Channel Link terminating at a Universal DS1 board
RSCL
Remote Socket Control Link terminating at a C-LAN board
RSL
Remote Socket Link teminating at a C-LAN board
SAP
System (Access) Port Link terminating at a Packet Data port
X.25
BX.25 Link terminating at a Packet Gateway port