Upgrading G3rV2, V3, V4 to R8r and Adding Memory 
1-20
Upgrade the software and hardware 
1
4. Type the day of month (1 through 31) in the 
Day of the Month:
 field 
and press 
Tab
 to move to the next field.
5. Type the current year in the 
Year:
 field and press 
TAB
 to move to the next 
field.
6. Type the current hour for a 24-hour clock in the 
Hour:
 field and press
 Tab
 
to move to the next field.
7. Type the current minute (0 through 59) in the 
Minute:
 field (seconds 
cannot be set). When done, press 
Tab
 to move to next field
8. Type standard or daylight savings in the 
Type
 field, according to the 
current time in the local time zone. For example, if currently on standard 
time, type standard.
9. Type the rule number in the 
Daylight Savings Rule
 field.
10. When all the information is correct, press 
Enter
.
11. Type display time
 
and press 
Enter 
to verify date and time data.
Set Core Dump Vector
1. Type set vector f spe-maint and press 
Enter 
to set the core dump vector to 
perform a core dump on any system restart. 
Enable TTI
NOTE:
Do this step only if the TTI is disabled and you want it enabled.
1. Type change system-parameters features and press 
Enter
 to change the 
TTI field back to its value before the upgrade.
Table 1-4.
English Month Names
Number
Name
Number
Name
1
January
7
July
2
February
8
August
3
March
9
September
4
April
10
October
5
May
11
November
6
June
12
December