DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Upgrading G3rV2, V3, V4 to R8r and Adding Memory 
1-21
Upgrade the software and hardware 
1
Release MMI (H/C only)
1. Type release board 
cabinet carrier slot and press 
Enter 
to release the 
circuit packs, which were busied out earlier.
Resolve Alarms
1. Type display alarms and press 
Enter
 to examine the alarm log. Resolve 
any alarms that may exist using 
DEFINITY Enterprise Communications 
Server Release 8 Maintenance for R8r. 
Check Link Status
1. Type display communication-interface links and press 
Enter
. Compare it 
with the earlier status.
2. Type status link 
number and press 
Enter
. Repeat this step for each link.
Enable Scheduled Maintenance
1. Type change system-parameters maintenance and press 
Enter
.
2. Type the appropriate time in the 
Start
 field to enable scheduled daily 
maintenance. Make sure the 
Save Translation
 field is set to daily.
Enable Customer Options and Alarm Origination 
to INADS
1. Get the DOSS order number of the upgrade from the project manager and 
ask the regional Customer Software Administration to complete the steps 
in the shaded box. See 
 
for telephone numbers.
NOTE:
As part of the system registration process, the INADS Database 
Administrator enables Alarm Origination and customer options.
2. When administration is completed, log in as craft at the 
Login:
 prompt.