Perle Systems SCS8C DC User Manual

Page of 460
 178
Serial Port Profiles
Input Signal Field Descriptions
See 
 for information about the 
I/O Extension
 tab.
Configure the following parameters:
Description
Provide a description of the channel, making it easier to identify. 
Data Options: Maximum 20 characters, including spaces
Latch
Latches (remembers) the activity transition (active to inactive or inactive to 
active). 
Data Options: None, Inactive-to-Active, Active-to-Inactive
Default: None
Invert Signal
When enabled, inverts the actual condition of the I/O signal in the status; 
therefore, an inactive status will be displayed as active.
Default: Disabled
Trigger
When the trigger condition is met, triggers the specified alarm action. 
Data Options: 
z
Disabled—No alarm settings. This is the default.
z
Inactive—When the expected Digital input is active, going inactive will 
trigger an alarm.
z
Active—When the expected Digital input is inactive, going active will 
trigger an alarm.
Default: Disabled
Auto Clear Mode
When enabled, automatically clears the alarm when the trigger condition 
changes; for example, if the 
Trigger
 is 
Inactive
 and the alarm is triggered, once 
the input becomes active again, the alarm will automatically be cleared 
Default: Enabled
Manual Clear 
Mode
When enabled, a triggered alarm must be manually cleared. 
Default: Disabled