Perle Systems SCS8C DC User Manual

Page of 460
 179
Serial Port Profiles
Output Signal Field Descriptions
See 
 for information about the 
I/O Extension
 tab.
Configure the following parameters:
Email
When enabled, sends an email alert to an email account(s) set up in the 
System
 
settings when an alarm is triggered or cleared. The email alert data includes the 
severity level and the value that caused the alarm to trigger or clear. The 
Email 
Alert
 is associated with 
Level Critical
.
Default: Disabled
Syslog
When enabled, sends a message to syslog when an alarm is triggered or 
cleared. The syslog entry includes the severity level and the value that caused 
the alarm to trigger or clear. The syslog message is associated with 
Level 
Critical
.
Default: Disabled
SNMP
When enabled, sends an SNMP trap when an alarm is triggered or cleared. The 
trap consists of the severity level and whether the alarm was triggered or 
cleared.
Default: Disabled
Description
Provide a description of the channel, making it easier to identify. 
Data Options: Maximum 20 characters, including spaces
Failsafe Action
When there has been no I/O activity within the specified time (set in the I/O 
InterfacesSettings on the Failsafe Timer tab) and the 
Failsafe Timer
 is 
triggered.
Data Options:
z
None—The state of the Digital/Relay output remains the same, no change.
z
Activate Output—Activates the channel.
z
Deactivate Output—Deactivates the channel. 
Default: None