Hand Held Products 2020/5620 User Manual

Page of 168
3 - 10
When the output sequence is 
Off, the bar code data is output to the host as the 
scanner decodes it.  
Note: This selection is unavailable when the Multiple Symbols Selection is 
turned on.
Output Sequence Example
In this example, you are scanning Code 93, Code 128, and Code 39 bar codes, 
but you want the scanner to output Code 39 1st, Code 128 2nd, and Code 93 
3rd, as shown below.
Note: Code 93 must be enabled to use this example.
You would set up the sequence editor with the following command line:
SEQBLK62999941FF6A999942FF69999943FF
The breakdown of the command line is shown below:
SEQBLKsequence editor start command
 Required
 On/Not Required
 * Off
A - Code 39
B - Code 128
C - Code 93