  SICLOCK
®
 TC 400  
 
Table 7-3 
Operator options and displays in the Parameters tab
Field/Button
Meaning/Instruction
Print table to text file
Output of the parameterization to a text file 
The currently displayed parameterization is output to a text file. The data can, 
for example, be further edited with Excel.
Notice
Parameterizations cannot be restored from these text files. To restore a 
parameterization, it must first have been saved in U600 format.
See Open/Save in General functions (Section 7.2).
Download parameters
(online connection 
required)
Download parameters of the connected device
The parameters of the connected device including the description data (e.g. 
texts in all languages) are downloaded. This can take several minutes. Implic-
itly the parameterization is downloaded again from the device.
Notice
The displayed parameterization data is overwritten. The archive data is not 
taken over from the device, i.e. the displayed archive data is retained. 
See also Establish/disconnect online connection (Section 7.2.1).
Refresh parameters
(online connection 
required)
Download parameters of the connected device without parameter description
The parameters of a connected device are downloaded without the descrip-
tion data. This can take several minutes.
Notice
The displayed parameterization data is overwritten. The archive data is not 
taken over from the device, i.e. the displayed archive data is retained.
See also Establish/disconnect online connection (Section 7.2.1).
Upload parameters
(online connection 
required)
Transfer writeable values of the loaded parameters to the connected device
The following values/parameters are not transferred to the device:
 Value of write-protected parameters
 Critical operating parameters
 Display parameters
• Command parameters
An online connection must be established for the transfer of the parameters 
and the configuration tool must have the appropriate authorization. See also 
Establish/disconnect online connection (Section 7.2.1) and Authoriza-
tion
 (Section 7.2.2).
Monitor actual values
(online connection 
required)
Monitor current value/status of actual values
After the monitoring is activated, the current values or states are cyclically 
read from the device and the display in the parameter tree and parameter 
table is refreshed.
See also Establish/disconnect online connection (Section 7.2.1).