Metabo KGS 255 Plus User Manual

Page of 64
30
ENGLISH
15. Technical Specifications
Voltage 
V
230 (1
50 Hz)
110 (1
50 Hz)
Current draw 
A
5.8
11.9
Fuse protection 
A
10 (time-lag) 16 
(time-lag) 
Motor capacity (power input P1, S6 20% - 5 min) 
kW 
1.3
1.3
Protection class 
IP
20 
20 
Degree of protection 
II 
II 
Saw blade speed 
 min
-1
5500
4720
Cutting speed 
 m/s
55
60
Saw blade diameter (outer) 
mm
210 
210 
Arbor bore 
mm
30 
30 
Dimensions 
Machine in packing 
Length / width / height 
Saw ready to operate, rotating table in 0°-position 
Length / width / height 
mm
mm
645/ 540 / 375
1020/ 508/ 470
645/ 540 / 375
1020/ 508/ 470
Maximum workpiece cross section 
Standard cross cuts 
width / height 
Mitre cuts (rotating table 45°
width / height 
Bevel cuts (track arm holder 45° left
width / height 
Compound mitre cuts (rotating table 45° / track arm holder 45 ° left)
width / height 
mm 
mm 
mm 
mm 
255/ 60 
177/ 60 
255/ 30 
177/ 30 
255/ 60 
177/ 60 
255/ 30 
177/ 30 
Weight 
Machine in packing 
Machine ready to work 
kg 
kg 
20.5
17
20.5
17
Permissible ambient temperature for operation 
Permissible temperature for transport and storage 
°
°
0 to + 40 
0 to + 40 
0 to + 40 
0 to + 40 
Noise emission according to EN ISO 3744
Sound power level L
WA
Sound pressure level at operator ear L
PA
dB (A)
dB (A)
109
96
109
96
Effective value of weighted acceleration
(vibration at handle)
m/s
2
< 2.5
< 2.5
Dust extractor (not included in standard delivery) 
Suction port diameter 
Minimum air volume flow 
Minimum vacuum at suction port 
Minimum air speed at suction port 
mm 
m
3
/h 
Pa 
m/s 
43,5 
550 
740 
20 
43,5 
550 
740 
20 
Flange laser
Max. output power
Wave length
Laser product class
Batteries
mW
nm
3 × type
1.0
650
2
AG13 / LR44
1.0
650
2
AG13 / LR44
This machine is specially designed for the high momentary loads of crosscutting. The motor reaches the stated power of 1200 watts 
at S6 20% 5 min (intermittend periodic duty-type with starting). This means that this saw can be operated for 1 minute at full-load 
rating (1200 watts) within a 5 minute operating period. The motor has to deliver these 1200 watts only under extreme load condi-
tions - during normal crosscutting it is subjected to much lower loads. With lower loads the duty cycle of the motor increases sub-
stancially. Thus, when used as specified, because of its high reserve capacity, overheating or overloading of the motor is not possi-
ble.