Testing for Leaks
Perform a leak test at least once each year whether the 
gas supply cylinder has been disconnected or not. In 
addition, anytime the gas cylinder is connected to the 
regulator or any part of the gas system is disconnected 
or replaced, conduct a leak test.
As a safety precaution, remember to always leak test 
your fireplace outdoors in a well-ventilated area. Never 
smoke or permit sources of ignition in the area while 
doing a leak test. Do not use a flame, such as a lighted 
match to test for leaks. Use only a leak testing solution 
as specified below.
Prepare a leak testing solution of sudsy water by 
1. 
mixing in a spray bottle half-liquid soap and half 
water.
Check and make sure all the control knobs are in 
2. 
the OFF position.
Turn  cylinder  valve  knob  counter  clockwise  one 
3. 
turn to open.
Apply leak-testing solution by spraying on joints of 
4. 
the gas delivery system.
Blowing  bubbles  in  the  soap  solution  indicates 
5. 
that a leak is present.
Stop  a  leak  by  tightening  the  loose  joint  or  by 
6. 
replacing the faulty part with a replacement part  
recommended by the manufacturer. Do not attempt 
to  repair  the  cylinder  valve  if  it  should  become  
damaged. The cylinder must be replaced.
If you are unable to stop a leak, shut off the gas 
7. 
supply at the cylinder valve. Remove the cylinder 
from the fireplace. Call an authorized gas appliance 
service technician or LP gas dealer. Do not use the 
appliance until the leak is corrected.
Push  in  and  turn  any  control  knob  to  release 
8. 
pressure in the hose and manifold.
Turn off the control knob.
9. 
Lighting Your Gas Fireplace
Read the safety information above before attempting 
to light your fireplace.
This  appliance  must  be  lit  by  hand.  When  lighting, 
follow these instructions exactly. Before lighting, smell 
around the appliance area for gas. Be sure to smell 
next to the base of the appliance, because some gas 
is heavier than air and will settle on the ground.
Locate the manual gas control valve, located on 
1. 
the outside of the , two inches from the base of 
the . (Look for a bright red knob.)
Place  a  burning  match  on  top  of  the  burner  in 
2. 
the  middle  where  ports  are  present.  DO  NOT 
HOLD  THE  MATCH  IN  YOUR  HAND.  For  natural 
gas appliances, turn on the ON/OFF valve slowly 
at the appliance. For LP appliances, turn the valve 
on the LP tank counterclockwise all the way and 
then  turn  “ON”  the  ON/OFF  valve  slowly  at  the 
appliance.
If the burner does not light before the match goes 
3. 
out, immediately turn the gas valve to “OFF”.
Wait  at  least  five  minutes  to  clear  out  any  gas. 
4. 
Then  smell  for  gas,  including  the  base  of  the 
appliance. If you smell gas, STOP! Follow Safety 
Information above. If you don’t smell gas, repeat 
Step 2 above.
To Turn Off the Appliance
Turn  the  ON/OFF  valve  to  the  “OFF”  position  at 
1. 
the appliance for the natural gas appliance.
For  an  LP  appliance,  turn  the  ON/OFF  valve  to 
2. 
the “OFF” position at the appliance and then turn 
the valve on the LP tank clockwise to the “OFF” 
position.
Do  not  use  this  appliance  if  any  part  has  been 
• 
underwater.  Immediately  call  a  qualified  service 
technician to inspect the appliance, and to replace 
any part which has been under water.