Amana AOCD2770 User Manual

Page of 32
4
Installation
Packing Material
Remove protective packing material from oven. Tape
residue can be cleaned with a soft cloth and alcohol.
Lean oven to each side and remove shipping base.
Oven Location
Choose a location based on following factors.
• Make sure there is adequate space for proper
installation.
• Carefully read all instructions before beginning
installation.
• Make sure cabinet base is level.
Cabinet Opening
Prepare the cabinet for wall oven.
A
B
C
E
D
F
A—52
3
/
8
 inches
B—25 inches
C—24 inches minimum
D—27 inches minimum
E—12
1
/
2
  inches minimum
F—3 inches minimum
Cabinet Opening
Electrical Supply Location
Electrical supply must be located in the area shown.
A
B
A
B
A—5 inches
B—16 inches
Electrical Supply Location
Electrical Connection Requirements
Line voltage must not exceed rated voltage. Line voltage
less than rated voltage will result in slow heating. Wiring
system must conform to U.L. Standards and National
Electrical Code. Installation must conform to all local,
municipal and state building codes, and local utility
regulations. Oven must be connected only to a supplied
circuit as specified on rating plate.
This oven requires 3 wires, 115/230-120/240 volts, 60
Hertz A.C. Unit is equipped with a No. 10 ground wire in
conduit. Oven should be fused separately from other
appliances on a 40 amp circuit minimum. Verify electric
power is off from fuse box to junction box until oven is
installed and ready to operate.