RINSE THE BREWER
1.
Press 
, then press 
 until the display shows 
BREW RINSE. 
2.
Press 
 to rinse the brewer.  The display shows 
RINSING until the oper-
ation is complete.
3.
CONTINUE.
TEST SWITCHES OR SENSORS
1.
Press 
, then press 
 until the display shows 
IN.MKPHL12.
2.
Actuate each switch or sensor to test its function:
As you actuate each input, the display element representing that switch 
blinks on.  Releasing the switch causes that element to blink off again.
3.
CONTINUE.
VIEW SUREVEND™ LAST RECORDED 
CALIBRATION VALUE
1.
Press 
SureVend until the display shows 
CAL.LST XXX.  XXX can be 
any number from 0 to 255, and represents the most recent value read from 
the sensor.  The lower the number the greater the sensor blockage.  A num-
ber of 255 means that there is a fatal problem with the SureVend™ interface 
board.  Ensure the SureVend™ interface PCB is properly connected to the 
main controller PCB.
2.
CONTINUE.
M = mug/cup sensor (if equipped)
K = freevend keyswitch
P = waste pail switch
H = high water tank level switch
L = low water tank level switch
1 = ring 1 cup sensor switch
2 = ring 2 cup sensor switch