Crane Merchandising Systems 675 User Manual

Page of 86
Test the Machine
HDC II Programming Guide
6730018
67
July, 2003
VIEW SUREVEND™ AVERAGE CALIBRATION 
VALUE
1.
Press 
, then press 
 until the display shows 
CAL.AVE XXX.  
XXX represents the average sensor calibration value (should be between 50 
and 255 for proper sensor operation - i.e. 51 through 254).  Although this 
number could go as low as 20, the SureVend™ system will be inoperative 
in this condition.
2.
CONTINUE.
CLEAR TANK ERRORS AND FILL THE TANK
1.
Press 
, then press 
 until the display shows 
TANK FILL.
2.
Press 
.  This clears any tank error and starts filling the tank, if neces-
sary.  If it is taking a long time to fill the tank AND THERE ARE NO 
LEAKS, you may see 
TANK ERR in the diagnostic list again.  Just press 
 again after making sure there are no other problems, such as a 
restriction in the water inlet line or a clogged water filter.
3.
CONTINUE.
TEST THE DISPLAY
1.
Press 
, then press 
 until the display shows 
DSPLY TEST.  The 
"DRINK BEING SERVED" lamp is lighted (if so equipped), and remains 
lighted until you leave this function.
2.
Press 
 to light all display segments; press 
 to turn them off.
3.
Pressing a NUMBER KEY on the control panel causes all segments to dis-
play that character.
4.
CONTINUE.