Mitsubishi Electronics 882.00273.00 User Manual

Page of 101
Mechanical Options Screen 
This screen allows the user to change the number of hoppers, the predetermined gate cycle 
time, and the mixer bump time for detecting high level. 
The gate cycle time has been measured and set at the factory, but might need to be adjusted if 
we change the mechanical design of the gate, solenoids, and air cylinders.  This setting will 
vary depending on whether you are using a gate or an auger. 
Figure 71: Typical Mechanical Options Screen 
 
Feeder Setup 
This screen allows you to modify the type of each feeder.  In most cases, the user will want to 
keep regrind on hopper 3 because that blender has been specifically designed to handle the 
regrind.  These settings should only be modified under special circumstances.    
If the blender is configured in “EZ Mode” then one hopper must be configured for Regrind 
and only one hopper must be configured for Virgin material.  If this is incorrect, a message 
will be given on the Recipe Screen. 
Figure 72: Typical Feeder Setup Screen 
 
Go back to  
Engineering Only 
Directory. 
Go back to  
Engineering 
Only Directory 
BF1-615.3 
Chapter 7: 6BAppendix 
89 of 101