This setting should not be modified except by the developer except under unusual 
circumstances. 
Figure 68: Typical Advanced Weight Options Screen 
101 
 
 
Feed Algorithm Options Screen 
This screen allows the user to configure how the blender metering algorithm works.  The user 
can adjust the Initial percentage of Target to Meter, the Allowed Underfeed value, the 
number of retries before Double Gate Time, the allowed Weight/Sec Drop, and the Out of 
Material retry limit. 
Figure 69: Typical Feed Algorithm Options Screen 
 
Feed Calibration Options Screen   
This screen allows you to perform the feeder calibrations for each feeder (in weight per 
second).  This is useful when the feed calibration is giving you an error message (most 
commonly caused by overfilling the hopper during the calibration).  Select a feeder and then 
follow instructions.  An error is shown if the current feeder calibration feed time was too 
short, the feed time was too long, or if the hopper weight exceeded 110% of the set batch 
weight.  In the case that the feeder exceeded 110% (maximum hopper weight) due to a high 
rate hopper then the “Batch % for Feeder Cal” setting might be set too high.  Consult the 
manufacturer if this problem arises.  The current feeder calibration values are also shown on 
this page.  It is not necessary to perform feeder calibrations.  The blender will 
automatically learn these values during the batch. 
Figure 70: Typical Feed Calibration Options Screen 
 
Weight Filter 
Adjust the limit 
for “Hopper Over 
Max Weight” 
Weight/Sec. 
Filter 
Adjust Settle 
Go back to  
Engineering Only 
Directory 
Go back to  
Engineering Only 
Directory 
Go back to  
Engineering Only 
Directory. 
BF1-615.3 
Chapter 7: 6BAppendix 